video
Brass Solenoid Valve Valve Body Gravity Casting
1653226440(1)
1653226456(1)
1/2
<< /span>
>

Brass Solenoid Valve Valve Body Gravity Casting

The 2W brass solenoid valve is a carefully produced solenoid valve by our company. While ensuring quality, the price is also very reasonable, and we also do a very comprehensive after-sales service. Choosing this product from our company will definitely not disappoint you.

Product Introduction

Brass solenoid valve valve body gravity casting

Item

Material

Production Process

Sintering Temperature

Mold

Custom

Brass solenoid valve valve body gravity casting

brass

Investment casting

880℃

To be customized

Yes

Available Materials

Low carbon stainless steel, titanium alloy (Ti, TC4), copper alloy, tungsten alloy, cemented carbide, high temperature alloy (718, 713)

Smoothness

Dimensional accuracy

Product density

Appearance treatment

Appropriate weight

Standard Ra6.3-12.5, special Ra3.2

CT3-7 class, the limit tolerance can reach ±0.10 according to customer requirements

8.9

According to customer requirements

0.08g -5kg

 

Production process of brass solenoid valve body and water glass investment casting parts

The 2W brass solenoid valve is a carefully produced solenoid valve by our company. While ensuring quality, the price is also very reasonable, and we also do a very comprehensive after-sales service. Choosing this product from our company will definitely not disappoint you. Brass solenoid valves are suitable for various light and heavy industrial conditions as well as building pipelines. Electromagnetic valves are widely used in fields such as chemical engineering, liquefied petroleum gas, vehicle and ship manufacturing equipment, water, petroleum, beer, pharmaceuticals, power, mechanical equipment valves, electronic industry valves, urban construction valves, industrial pipeline valves, general components, industrial equipment, fire protection HVAC, filtration equipment, environmental protection equipment, etc.

Product Name

2WBrass Solenoid Valve

Product model

ZS

Nominal diameter

DN2.5-50mm

Pressure range

1.6MPa

body material

Copper, cast iron, cast steel, stainless steel

 

Product Introduction

Two normally closed solenoid valves, powered off to close and powered on to open. The product is produced in series, with small volume, large flow rate, and a wide range of applications,

Valve body material, copper, SS304 stainless steel pipe,

Environmental temperature from 0 ° C to 65 ° C, medium temperature from 0 ° C to 120 ° C

Pressure range: maximum pressure resistance 1.0MPA, working pressure 0-0.8MPA

Installation: According to the arrow marked on the valve, it can be installed arbitrarily. To enhance service life, it is best to install the coil upwards and horizontally.

Voltage: AC24V/110V/220V/230V/240V 50/60HZ DC24V/12V

Seals: Various types such as NBR, VITON, EPDM, etc. can be used for switch control that is suitable for different fluids.

 

Technical parameters

Model

2W-2.5

2W-4

2W-10

ZS-15

2W-20

2W-25

2W-35

2W-40

2W-50

Using fluids

Air, water, oil, hot water, gas

Action mode

Direct action type

type

Normally closed and normally open

Flow aperturemm

2.5

4

16

20

25

35

40

50

C V value

0.23

0.6

4.8

7.6

12

24

29

48

port size

1/8"

1/4"

3/8"

1/2"

3/4"

1"

11/4"

11/2"

2"

Using fluid viscosity

Under 20CST

Use pressure

Water (hot water):0~10 air:0~10 o:0~5Kgf/cm2

Maximum pressure resistance

16kgf/cm2

medium temperature

-5~120°C

Using voltage range

±10% voltage :AC220V AC110V DC24V

Contact with the factory for other voltages

Body material

Brass stainless steel

Oil seal material

NBR or VITON

 

product-553-142

product-553-316

Pipe diameter (G)

Flow path (MM)

Minimum pressure (MPA)

Pressure(MPA) AC

Pressure(MPA) DC

Length * Width * Height(MM)

Material quality

1/2

15

0

0.8

0.8

51*55*102

Copper

3/4

20

0

0.8

0.8

62*55*102

Copper

1

25

0

0.8

0.8

67*55*112

Copper

11/4

35

0

0.8

0.8

90*77*130

Copper

11/2

40

0

0.8

0.8

106*87*164

Copper

2

50

0

0.8

0.8

123*93*176

Copper

1/2

15

0

0.8

0.8

69*57*107

stainless steel

3/4

20

0

0.8

0.8

73*57*115

stainless steel

1

25

0

0.8

0.8

98*77*125

stainless steel

11/4

35

0

0.8

0.8

115*87*1153

stainless steel

11/2

40

0

0.8

0.8

121*94*162

stainless steel

2

50

0

0.8

0.8

168*123*187

stainless steel

Specification of flange connection

Caliber

Minimum pressure(mpa)

Maximum pressure(MPA)

Length

A(MM)

Width

E(MM)

Height

H(MM)

 

15

0

0.8

107

95

150

stainless steel

20

0

0.8

107

102

150

stainless steel

25

0

0.8

138

108

165

stainless steel

32

0

0.8

149

131

200

stainless steel

40

0

0.8

160

141

220

stainless steel

50

0

0.8

186

160

240

stainless steel

notes

The normal type is normally closed, please specify the normally open type separately, and the explosion-proof type is marked with the EX symbol

 

Possible faults and their troubleshooting methods

Trouble

Shooting

Methods for fault causes

turn on electricity

The solenoid valve cannot be opened.

The power supply voltage is too low

Burnout of coil

the medium pressure is too low

Adjust the voltage to within the range of use

Replace the coil

Increase the pressure of pipeline medium

Turn off power

The valve cannot be closed or closes poorly

The medium pressure is too high

Membrane damaged or foreign object stuck

Tower spring deflection above the diaphragm

reduces the pressure of the pipeline medium

Replace with a new diaphragm to remove foreign objects

Repositioning installation

 

Installation instructions:

1. When installing, the solenoid valve coil should be facing upwards and kept in a vertical position. The arrow or mark on the solenoid valve should be consistent with the flow direction of the pipeline and should not be installed in areas with splashes or leaks.

2. The working medium of the solenoid valve should be clean and free of particulate impurities. The dirt and filters on the surface of the solenoid valve components should be regularly cleaned.

3. When the solenoid valve malfunctions, it is best to install a bypass device in order to isolate the solenoid valve in a timely manner and ensure the normal operation of the system.

4. In pipeline systems, the diameter of the solenoid valve installed on the branch should be smaller than the diameter of the main pipeline valve.

5. Before installing the solenoid valve, the pipeline must be cleaned thoroughly. It is recommended to install a filter in front of the valve and a drain valve in the steam pipeline.

6. Valves should not be installed in the low recesses of the pipeline to prevent steam condensation, impurities, etc. from settling inside the valve and hindering its operation.

7. The ordinary type cannot be used in explosive hazardous situations.

8. In the case of insufficient pipeline rigidity, it is recommended to fix the pipeline in front of the valve with a bracket to avoid vibration caused by the operation of the solenoid valve.

9. Before installation, it is important to carefully read the product label, carefully read the user manual, and determine whether the product meets the conditions for use.

10. Pressure gauges need to be installed on the front and rear pipelines of the solenoid valve to observe the pipeline pressure.

 

Instructions for use and maintenance

1. It is recommended that the using unit assign a dedicated person to be responsible for the use and maintenance.

2. After the installation of the solenoid valve, it is necessary to conduct several experiments with the medium and confirm that it is normal before it can be put into formal use.

3. Regularly clean the dirt inside and outside the large valve, as well as the suction surface of the armature. Be careful not to damage the sealing surface.

4. When the solenoid valve is not used for a long time, the manual valve in front of the valve should be closed. When it is reactivated, the steam solenoid valve should drain the condensate clean and perform several trial actions. It can only be put into use after the switch is normal.

5. When the solenoid valve is removed from the pipeline and not in use, the internal parts should be wiped clean and stored with compressed air.

6. When used for a long time, if the seal between the piston and the valve seat is not good, the sealing surface of the piston can be ground flat again, and then ground with the valve seat.

7. When working, attention should be paid to the pressure gauges before and after the valve. The working pressure should not exceed the rated pressure, and the working pressure difference must be within the range of the rated pressure difference. When the working pressure exceeds the rated pressure or the working pressure difference exceeds the rated differential, the solenoid valve should be stopped and the front and rear manual valves should be closed to prevent the solenoid valve from exploding and leaking.

 

Ordering Notice

1. Please indicate the model, nominal diameter, nominal pressure, working medium, working pressure difference, medium temperature, power supply voltage and frequency, and medium viscosity when placing an order.

2. The voltage of the solenoid valve during normal operation is 220V. If it exceeds this range, please indicate the voltage fluctuation when placing an order. Other specifications of power supply voltage can be specially ordered.

3. If the opening time of the valve is more than 12 hours, please choose a normally open solenoid valve. When there are flammable and explosive materials in the surrounding environment, please choose explosion-proof solenoid valves

When the usage situation is very important or the environment is complex, please provide design drawings and detailed parameters as much as possible, and our experts from Fengquan Company will review and control it for you.

We are the manufacturer of Brass solenoid valve valve body gravity casting, if you need more information please contact us!

 

Detection Systems

 

1661141928831

 

Copper Silica Sol Investment Casting

 

Copper Silica Sol Investment Casting

Copper Silica Sol Investment Casting1

 

Send Inquiry

(0/10)

clearall